Midsize electrical inverter systems for powering up to 375 to 600 watts of incandescent, fluorescent, induction or LED lighting loads. Pulse width modulated (PWM) output
design provides clean, 60 Hz. sinusoidal emergency power to loads. All models are designed for fast, easy wall mounting.
design provides clean, 60 Hz. sinusoidal emergency power to loads. All models are designed for fast, easy wall mounting.
Resources
Heavy duty steel cabinet is finished in white baked-on powder Coat paint providing scratch and corrosion resistance
Input
• Input Voltages: Universal 120 or 277VAC, 60Hz (User selectable
with two jumper wires provided)
• Input Frequencies: 60Hz ±2%
• Input Surge Protection: Meets UL924
• Input Protection: Provided by Service Panel rated at 20 amps maximum
Output
• Output Voltages: 120 or 277VAC, 60Hz
• Efficiency Rating: 98% at full rated load (line)
• Waveform: Sinusoidal (digitally controlled)
• Static Voltage: ±5% during battery discharge. 0-100% linear load
• Output Frequencies: 60Hz. ±0.3Hz during emergency cycle
• Output Distortion: Less than 3% THO (linear load)
• Transfer Time: Less than 1.0 second
• Load Power Factor Range: 0. 88 Lead to 0. 88 Lag
• Minimum Loading: 0% of rated system capacity
• Output Protection: Circuit breaker and overload shut down protection
• Input Voltages: Universal 120 or 277VAC, 60Hz (User selectable
with two jumper wires provided)
• Input Frequencies: 60Hz ±2%
• Input Surge Protection: Meets UL924
• Input Protection: Provided by Service Panel rated at 20 amps maximum
Output
• Output Voltages: 120 or 277VAC, 60Hz
• Efficiency Rating: 98% at full rated load (line)
• Waveform: Sinusoidal (digitally controlled)
• Static Voltage: ±5% during battery discharge. 0-100% linear load
• Output Frequencies: 60Hz. ±0.3Hz during emergency cycle
• Output Distortion: Less than 3% THO (linear load)
• Transfer Time: Less than 1.0 second
• Load Power Factor Range: 0. 88 Lead to 0. 88 Lag
• Minimum Loading: 0% of rated system capacity
• Output Protection: Circuit breaker and overload shut down protection
BAA & BABA Compliant BUILT IN Ohio, USA.
Mid Sized Electrical Inverter SystemsÂ
Emergency lighting Inverters
Mid Sized Electrical Inverter SystemsÂ
Emergency lighting Inverters
Watts
- 375 w
- 600 w
Color / Finish
- Custom
- White
Emergency Type
- Emergency Inverters
Listings
- UL
Materials
- Steel
Ratings & Compliance
- Build America Buy America (BABA)
- Buy American Act (BAA)
- Damp
- Made in America
- NFPA 101
- Title 20
Special Programs
- Quick Ship
Voltage
- 120 V
- 277 V
Warranty
- 7 yr